Key Highlights

• Heart failure hospitalisation rate of 1% at one year in 100 patients with small aortic annuli

• Mean pressure gradient of 8.9 mmHg maintained at one year with no moderate or severe paravalvular leak

• 97% of patients were free from moderate or severe prosthesis-patient mismatch at 30 days

• Left ventricular mass regressed by 24% at one year in a cardiac MRI substudy of 64 patients

Anteris Technologies Global Corp. (NASDAQ:AVR, ASX:AVR) announced on 23 November 2026 one-year clinical and hemodynamic outcomes for its DurAVR Transcatheter Heart Valve (THV) in 100 patients with severe aortic stenosis and small aortic annuli. The late-breaking data were presented at PCR London Valves 2026.

One-Year Clinical Outcomes in a Complex Patient Population

At one year, 1% of patients had been hospitalised for heart failure. The DurAVR THV maintained a mean pressure gradient of 8.9 mmHg and a mean effective orifice area of 2.2 cm², with no moderate or severe paravalvular leak observed and no valve-related mortality reported. At 30 days, 97% of patients were free from moderate or severe prosthesis-patient mismatch.

The patient population was clinically complex, with 61% in NYHA class III/IV at baseline, a mean STS-PROM score of 4.7%, and the cohort including heavy calcification and bicuspid anatomy at 9%. Patients were pooled from the EMBARK and early feasibility studies conducted in the United States and Europe.

Symptoms improved over the study period: the proportion of patients in NYHA class I/II rose from 39% at baseline to 96% at one year, with 81% of patients experiencing symptom improvement.

Clinical Events and Cardiac Remodelling Data

All-cause mortality at one year was 6%, comprising two cardiovascular mortalities, two non-cardiac infections, one cancer and one car accident. Stroke occurred in 3% of patients and new permanent pacemaker implantation in 9%. No moderate or severe hemodynamic valve deterioration was observed.

In a cardiac magnetic resonance substudy of 64 patients, left ventricular mass regressed by 24% at one year. The company stated that LV mass in the patients evaluated was similar to that reported in matched controls without aortic valve disease.

Comparative Context and Pivotal Trial

The company noted that cross-trial comparisons should be interpreted with caution. It referenced a pooled analysis of more than 3,400 patients in the PARTNER trials where the one-year heart failure hospitalisation rate was 6.7%, and the SMART trial of small-annulus patients where heart failure hospitalisation was 4.1% with the Evolut valve and 3.5% with the SAPIEN valve.

The DurAVR THV is currently being studied in the PARADIGM Trial, a prospective randomised controlled trial enrolling approximately 1,000 patients in a head-to-head comparison against commercially available TAVR valves across the United States and Europe. The primary composite endpoint assesses all-cause mortality, all stroke and cardiovascular hospitalisation at one year.

The DurAVR THV is intended for investigational use only and is not available for commercial use or sale worldwide. Early or pooled clinical results may not be predictive of future results.