ReNerve Limited (ASX:RNV), an Australian medical device company focused on peripheral nerve repair, has reported positive interim 12-month results from its ongoing preclinical study of the NervAlign® Nerve Guide Matrix, with animals treated showing similar walking ability and nerve signal return to those treated with an autologous nerve graft across a 4cm critical-sized defect gap.

Key Points

  • 12-month preclinical sheep data show nerve regeneration and return of nerve function across a 4cm gap using NervAlign® Nerve Guide Matrix
  • Animals treated with NervAlign showed similar gait to animals treated with autologous nerve grafts and untreated animals at 12 months
  • Nerve conduction testing detected both sensory and motor nerve signals in NervAlign-treated animals, with similar results in the autologous graft group
  • Preliminary histological assessment found regrown vascularisation and axonal structures along the length of implants and into the distal nerve segment
  • Additional animals are scheduled for assessment in November 2026, with further results to follow

Preclinical Study Design and Scope

The study evaluated a 4cm section of the NervAlign® Nerve Guide Matrix implanted in a sheep peripheral nerve model, compared with an autologous nerve graft control. The study included six implants in total, comprising three NervAlign® Nerve Guide Matrix implants and three autologous nerve grafts. The study is assessing whether the NervAlign® Nerve Guide Matrix can support nerve regeneration across a 4cm gap without requiring a donor nerve. Because of the small number of animals reported to date, the company stated that formal statistical assessment is not yet possible. The use of a large animal model was noted as relevant to human application.

12-Month Functional and Histological Findings

All animals recovered well following surgery and were walking freely within hours of the procedure. At 12 months, nerve conduction testing detected both sensory and motor nerve signals in animals treated with the NervAlign® Nerve Guide Matrix, demonstrating that nerve signals were able to travel across the repaired area. Preliminary histological assessment found regrown vascularisation and axonal structures in sections taken along the length of the implants and into the distal nerve segment. In one NervAlign® animal, a minimal area of inflammation was observed within the implant at 12 months, although axonal regrowth was present throughout the length of that implant. The company disclosed it is investigating the finding as part of ongoing histological analysis.

Next Steps and Regulatory Status

According to the filing, additional animals are scheduled to be explanted in late November 2026. The company expects to provide a further update once data from the additional animals and the full histological analysis, including investigation of the inflammatory finding, are available. The filing states that the NervAlign® Nerve Guide Matrix is in development and is not approved for sale in any jurisdiction. ReNerve disclosed it continues to consult with regulatory authorities on its path forward to regulatory marketing approval. The company noted that preclinical results are not necessarily predictive of outcomes in humans. More detailed staining and analysis is described as in progress.