Anteris Technologies Global Corp. (ASX:AVR) has disclosed one-year clinical and hemodynamic outcomes for its DurAVR Transcatheter Heart Valve (THV) in 100 patients with severe aortic stenosis and small aortic annuli, with a heart failure hospitalisation rate of 1% at one year, no valve-related deaths, and no moderate or severe paravalvular leak reported through the same period.

Key Points

  • Heart failure hospitalisation rate of 1% at one year in 100 patients with small aortic annuli (annulus area 404 ± 37 mm²)
  • Mean pressure gradient of 8.9 mmHg and mean effective orifice area of 2.2 cm² maintained at one year, with no valve-related deaths
  • 96% of patients achieved NYHA class I/II at one year, up from 39% at baseline
  • Left ventricular mass regressed by 24% at one year in a cardiac MRI substudy of 64 patients
  • Results presented by Rishi Puri, MD, PhD, of Cleveland Clinic at PCR London Valves on 22 November 2026

One-Year Clinical Outcomes in 100 Small Aortic Annuli Patients

The data, pooled from the EMBARK and early feasibility studies conducted in the United States and Europe, showed all-cause mortality of 6% at one year, comprising two cardiovascular mortalities, two non-cardiac infections, one cancer and one car accident. Stroke was reported in 3% of patients, and new permanent pacemaker implantation occurred in 9%. At baseline, 61% of patients were in NYHA class III/IV, the mean STS-PROM score was 4.7 ± 4.0%, and the cohort included patients with heavy calcification and bicuspid anatomy at 9%. No moderate or severe hemodynamic valve deterioration was observed at one year.

Hemodynamic Performance and Cardiac Remodelling Data

Mean pressure gradient fell from 48.1 ± 17.0 mmHg at baseline to 8.9 ± 4.3 mmHg at one year, while mean effective orifice area increased from 0.8 ± 0.2 cm² to 2.2 ± 0.9 cm². At 30 days, 97% of patients were free from moderate or severe prosthesis-patient mismatch. In a cardiac magnetic resonance substudy involving 64 patients, left ventricular mass regressed by 24% at one year, with levels reported as similar to those in matched controls without aortic valve disease, according to the filing. No moderate or severe paravalvular leak was observed through one year.

PARADIGM Pivotal Trial Actively Enrolling Patients

The DurAVR THV is currently being studied in the pivotal PARADIGM Trial (ClinicalTrials.gov ID NCT07194265), described in the filing as a prospective randomised controlled trial evaluating the safety and effectiveness of the DurAVR THV compared to commercially available TAVR valves. The trial is a randomised, head-to-head comparison actively enrolling patients across the United States and Europe. The late-breaking abstract was presented during the TAVI Hotline – Part 1 session at PCR London Valves on 22 November 2026, with 30-day data from the same cohort having previously been presented at PCR London Valves 2025.